The function and inner working of piezoelectric sensors
Piezoelectricity is the phenomenon where materials generates a voltage whenever a strain is created within the material. Not only can this be used to sense mechanical forces, but also to quantify biomolecules.
The most common piezoelectric material used is quartz (). Quartz have a unique crystal structure off silicon-oxygen tetrahedras. Whenever mechanical stress is applied to quartz, it shifts the atoms which creates dipoles within the material. Within quartz, these dipoles align to create a net electric field within the quartz. This can be detected as a voltage over the crystal. The opposite is also true. Whenever an electric field, e.g. by an voltage, is applied over the quartz crystal, dipoles within the material negates the electric field within the material. This leads to mechanical deformation. The phenomenon is known as the piezoelectric effect.
Crystal oscillators
If a voltage matching the polarisation of the crystal is applied, the crystal will compress, creating an oposing voltage. If the applied voltage is removed, the crystall decompresses and generates a voltage similar to the one orignally applied. This voltage will simiary compress the crystall. The compression of the crystall will create an oposing voltage which will decompress the crystall. This will continue, creating a dampened oscillating system. By continously amplifying the signal we can keep the quartz crystal oscillating. This can be done by attaching two electrodes to the crystal and using a positive feedback op-amp circuit. The quartz crystal will then keep resonating at a natural frequency.
Making a biosensor from a quartz crystal
The natural frequency of a quartz crystal can be decreased by loading a mass at the side of the crystal. In practice, this is done by attaching an additional mass on the electrode connected to the quartz crystal. Assuming a rigid mass, a german physicist named Sauerbrey were able to find that the frequency changes by:
- - the change in the crystal's resonance frequency (Hz).
- - the crystal's resonant frequency (Hz).
- - The mass loaded on the crystal surface (kg).
- - the area of the electrode attached to the crystal. (m²).
- - the density of quartz (kg/m³).
- - the shear modulus of quartz (Pa).
All the variables are constant for a given quartz crystal. As such, you can measure the mass of the loaded object by recording the change in frequency a given quartz crystal experiences. This type of sensor is know as a Quartz Crystal Microbalance (QCM). By then functionalizing the surface of the electrode you can let biomolecules bind to it. This is done inside of an aqueous enviroment where an inlet and an outlet continously introduce the sample to be analyzed, e.g. within a microchannel device. In theory, this QCM are sensetive enough to detect changes in the nano gram scale.